http://dx.doi.org/10.4322/sc.2011.009

 

Detection in fast gas chromatography and comprehensive two-dimensional gas chromatography

Pedroso, Marcio Pozzobon

Palavras-chave: Gas chromatography, detectors, fast gas chromatography, comprehensive two-dimensional gas chromatography.

Resumo: The fast gas chromatography and the comprehensive two-dimensional gas chromatography generate peaks much narrower than in conventional gas chromatography. In these techniques, the peak width (at baseline) commonly observed ranges from 1 s to 50 ms, reaching values as small as units of milliseconds. The flame ionization detector and the time of flight mass spectrometer do not present limitation to detect such narrow peaks; however, other detectors present some limitations. Peak distortion, peak tailing and the low quality of the peak mass spectra are the main problems observed. In the present paper it will be presented the basic characteristics of the detectors for gas chromatography and their use to detect narrow peaks.


Referências Bibliográficas

1. Mastovska K, Lehotay SJ. Practical approaches to fast gas chromatography–mass spectrometry. Journal of Chromatography A 2003; 1000(1-2):153-180. http://dx.doi.org/10.1016/S0021-9673(03)00448-5
2. Sequinel R, Hatanaka RR, Gualtieri CE, Flumignan DL, Oliveira JE, Passaretti Filho J. Cromatografia gasosa ultrarrápida: uma visão geral sobre parâmetros, instrumentação e aplicações. Química Nova 2010; 33.(10):2226:2232. http://dx.doi.org/10.1590/S0100- 40422010001000036.
3. Matisovà E, Dömötörová M. Fast gas chromatography and its use in trace analysis. Journal of Chromatography A 2003; 1000(1-2):199-221. http://dx.doi.org/10.1016/ S0021-9673(03)00310-8
4. Dömötörová M, Matisovà E. Fast gas chromatography for pesticide residues analysis. Journal of Chromatography A 2008; 1207(1-2):1‑16. PMid:18801490. http://dx.doi. org/10.1016/j.chroma.2008.08.063
5. Dallüge J, Beens J, Brinkman UAT. Comprehensive two-dimensional gas chromatography: a powerful and versatile analytical tool. Journal of Chromatography A 2003.; 1000(1-2):69-108. http://dx.doi.org/10.1016/ S0021-9673(03)00242-5
6. Pedroso MP, Godoy LAF, Fidelis CHV, Ferreira EC, Poppi RJ, Augusto F. Cromatografia gasosa bidimensional abrangente (GC × GC). Química Nova 2009; 32(2):422-430. http://dx.doi.org/10.1590/ S0100-40422009000200029
7. Zini CA. Cromatografia gasosa bidimensional. Scientia Chromatographica 2009; 1:31-49.
8. Adahchour M, Beens J, Vreuls RJJ, Brinkman UATh. Recent developments in comprehensive two-dimensional gas chromatography (GC × GC): I. Introduction and instrumental set-up. TrAC Trends in Analytical Chemistry 2006; 25(5):438-4564. http://dx.doi.org/10.1016/j.trac.2006.03.002
9. Adahchour M, Beens J, Vreuls RJJ, Brinkman UATh. Recent developments in comprehensive two-dimensional gas chromatography (GC × GC): II. Modulation and detection. TrAC Trends in Analytical Chemistry 2006; 25(5):540-553. http://dx.doi. org/10.1016/j.trac.2006.04.004
10. Adahchour M, Beens J, Vreuls RJJ, Brinkman UATh. Recent developments in comprehensive two-dimensional gas chromatography (GC × GC): III. Applications for petrochemicals and organohalogens. TrAC Trends in Analytical Chemistry 2006; 25(5):726‑741. http://dx.doi.org/10.1016/j.trac.2006.03.005
11. Adahchour M, Beens J, Vreuls RJJ, Brinkman UATh. Recent developments in comprehensive two-dimensional gas chromatography (GC × GC): IV. Further applications, conclusions and perspectives. TrAC Trends in Analytical Chemistry 2006; 25(5):821‑840. http://dx.doi.org/10.1016/j.trac.2006.03.003
12. McNair HM, Miller JM. Basic gas chromatography. 2.nd ed. New Jersey: John Wiley & Sons; 2009. http://dx.doi.org/10.1002/9780470480106
13. Grob RL, Barry EF., editor. Modern pratice of gas chromatography. 4th ed. New Jersey: John Wiley & Sons; 2004.
14. Hinshaw JV. Handling fast peaks. LC-GC Europe 2002; 15.(3):152-155.
15. Kirchner M, Matisova E, Hrouzkova S, Zeeuw J. Possibilities and limitations of quadrupole mass spectrometric detector in fast gas chromatography. Journal of Chromatography A 2005; 1090(1-2):126-132. PMid:16196141. http://dx.doi.org/10.1016/j.chroma.2005.06.090
16. Amirav A, Jing H. Pulsed flame photometer detector for gas chromatography. Analytical Chemistry 1995.; 67(18):3305-3318. http://dx.doi.org/10.1021/ ac00114a030
17. Dyson N. Peak distortion, data sampling errors and the integrator in the measurement of very narrow chromatographic peaks. Journal of Chromatography A 1999; 842(1-2):321-340. http://dx.doi.org/10.1016/ S0021-9673(99)00299-X
18. Dallüge J, Vreuls RJJ, Iperen DJ van, Rijn M van, Brinkman UATh. Resistively heated gas chromatography coupled to quadrupole mass spectrometry. Journal of Separation Science 2002; 25(9):608-614. http://dx.doi. org/10.1002/1615-9314(20020601)25:9%3C608::AIDJSSC608% 3.E3.0.CO;2-R
19. Cordero C, Bicchi C, Joulain D, Rubiolo P. Identification, quantitation and method validation for the analysis of suspected allergens in fragrances by comprehensive two-dimensional gas chromatography coupled with quadrupole mass spectrometry and with flame ionization detection. Journal of Chromatography A 2007; 1150(1-2):37-49. PMid:16973171. http://dx.doi.org/10.1016/j.chroma.2006.08.079
20. Mondello L, Tranchida PQ, Dugo P, Dugo G. Rapid, micro-scale preparation and very fast gas chromatographic separation of cod liver oil fatty acid methyl esters. Journal of Pharmaceutical and Biomedical Analysis 2006; 41(5):1566-1570. PMid:16500061. http://dx.doi.org/10.1016/j.jpba.2006.01.027
21. Deursen M van, Beens J, Janssen HG, Leclercq PA, Cramers CA. Evaluation of time-of-flight mass spectrometric detection for fast gas chromatography. Journal of Chromatography A 2000; 878(2):205-213. http://dx.doi.org/10.1016/S0021-9673(00)00300-9
22. Dagan S, Amirav A. Fast, very fast, and ultra-fast gas chromatography-mass spectrometry of thermally labile steroids, carbamates, and drugs in supersonic molecular beams. Journal of the American Society for Mass Spectrometry 1996; 7(8):737-752.
23. Phillips JB, Beens J. Comprehensive two-dimensional gas chromatography: a hyphenated method with strong coupling between the two dimensions. Journal of Chromatography A 1999; 856(1-2):331-347. http://dx.doi.org/10.1016/S0021-9673(99)00815-8
24. Mühlen C von, Khummueng W, Zini CA, Caramão EB, Marriott PJ. Detector technologies for comprehensive two-dimensional gas chromatography. Journal of Separation Science 2006; 29(12):1909-1921. http://dx.doi.org/10.1002/jssc.200500443
25. Mondello L, Tranchida PQ, Dugo P, Dugo G. Comprehensive two-dimensional gas chromatography-mass spectrometry: A review. Mass Spectrometry Reviews 2008. 27(2):101-124. PMid:18240151. http://dx.doi.org/10.1002/mas.20158
26. Kristenson EM, Korytar P, Danielsson C, Kallio M, Brandt M, Mäkelä J et al. Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds. Journal of Chromatography A 2003; 1019(1-2):65-77. http://dx.doi.org/10.1016/S0021-9673(03)01237-8
27. Frysinger GS, Gaines RB. Comprehensive two-dimensional gas chromatography with mass spectrometric detection (GC x GC/MS) applied to the analysis of petroleum. Journal of High Resolution Chromatography 1999; 22(5):251-255.
28. Shellie RA, Marriott PJ, Huie CW. Comprehensive two-dimensional gas chromatography (GC×GC) and GC×GC-quadrupole MS analysis of Asian and American ginseng. Journal of Separation Science 2003; 26(12-13):1185-1192. http://dx.doi.org/10.1002/jssc.200301404
29. Purcaro G, Tranchida PQ, Ragonese C, Conte L, Dugo P, Dugo G, Mondello L. Evaluation of a Rapid-Scanning Quadrupole Mass Spectrometer in an Apolar × Ionic-Liquid Comprehensive Two-Dimensional Gas Chromatography System. Analytical Chemistry 2010; 82(20):8583-8590. PMid:20873720. http://dx.doi.org/10.1021/ac101678r
30. Mühlen C von, Zini CA, Caramão EB, Marriott PJ. Comparative study of Eucalyptus dunnii volatile oil composition using retention indices and comprehensive two-dimensional gas chromatography coupled to time-of-flight and quadrupole mass spectrometry. Journal of Chromatography A 2008; 1200(1):34-42. PMid:18541252. http://dx.doi.org/10.1016/j.chroma.2008.05.070
31. Ryan D, Shellie R, Tranchida P, Casilli A, Mondello L, Marriott P. Analysis of roasted coffee bean volatiles by using comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry. Journal of Chromatography A 2004; 1054(1-2):57-65. PMid:15553131