https://dx.doi.org/10.4322/sc.2016.031
Bead injection technique for automation of sample treatment
Segundo, Marcela A.
Palavras-chave: Sample treatment, automation, bead injection, flow injection analysis.
Resumo: Sample treatment is one of the most time-consuming steps in the analytical process. The bead injection technique targets the miniaturization of this step, bringing innovative features when compared to previous flow schemes where sorbent renewal is not feasible. The advantages and disadvantages of the bead injection technique are critically addressed, along with strategies to implement the utilization of different types of sorbent. Applications to real samples are also highlighted with detailed characterization of the proposed flow systems.
Referências Bibliográficas
[1] Ruzicka J, Scampavia L. From flow injection to bead injection. Anal. Chem. 1999;71(7):257A-63A.
[2] Yu YL, Jiang Y, He RH. Development of a miniature analytical system in a lab-on-valve for determination of trace copper by bead injection spectroscopy. Talanta. 2012;88:352-57.
[3] Gutzman Y, Carroll AD, Ruzicka J. Bead injection for biomolecular assays: Affinity chromatography enhanced by bead injection spectroscopy. Analyst. 2006;131(7):809-15.
[4] Vidigal SSMP, Toth IV, Rangel AOSS. Sequential injection lab-on-valve platform as a miniaturisation tool for solid phase extraction. Anal. Methods. 2013;5(3):585-97.
[5] Miro M, Oliveira HM, Segundo MA. Analytical potential of mesofluidic lab-on-a-valve as a front end to column-separation systems. Trac-Trends Anal. Chem. 2011;30(1):153-64.
[6] Oliveira HM, Miro M, Segundo MA, Lima JLFC. Universal approach for mesofluidic handling of bead suspensions in lab-onvalve format. Talanta. 2011;84(3):846-52.
[7] Quintana JB, Miro M, Estela JM, Cerda V. Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis. Anal. Chem. 2006;78(8):2832-40.
[8] Oliveira HM, Segundo MA, Lima JLFC, Miro M, Cerda V. On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach. J.Chromatogr.A. 2010;1217(22):3575-82.
[9] Ramdzan AN, Barreiros L, Almeida MIGS, Kolev SD, Segundo MA. Determination of salivary cotinine through solid phase extraction using a bead-injection lab-on-valve approach hyphenated to hydrophilic interaction liquid chromatography. J Chromatogr A. 2016;1429:284-91.
[10] Oliveira HM, Segundo MA, Lima JLFC, Miro M, Cerda V. Exploiting automatic on-line renewable molecularly imprinted solidphase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs. Anal. Bioanal. Chem. 2010;397(1):77-86.
[11] Boonjob W, Sklenarova H, Barron L, Solich P, Smith N. Renewable sorbent material for solid phase extraction with direct coupling of sequential injection analysis-bead injection to liquid chromatography-electrospray ionization tandem mass spectrometry. Anal. Bioanal. Chem. 2015;407(19):5719-28.
[12] Vichapong J, Burakham R, Srijaranai S, Grudpan K. Sequential injection-bead injection-lab-on-valve coupled to high-performance liquid chromatography for online renewable micro-solid-phase extraction of carbamate residues in food and environmental samples. J. Sep. Sci. 2011;34(13):1574-81.
[13] Boonjob W, Miro M, Segundo MA, Cerda V. Flow-through dispersed carbon nanofiber-based microsolid-phase extraction coupled to liquid chromatography for automatic determination of trace levels of priority environmental pollutants. Anal. Chem. 2011;83(13):5237-44.